MK-LXS8

Cechy

  • HDPE, UV stabilized outer jacket with low coefficient of friction
  • Loose tubes (and fillers), SZ stranded around the CSM
  • Each PBT tube containing up to 12 optical fibres
  • Smallest outer diameter for blowing into 10mm (ID) ducts

Aplikacje / Zastosowania

  • Microduct cabling air-blowing system application
  • Metro networks
  • Flexible network design
  • Distribution network

Parametry techniczne

Cable designs

Variant Quantity [pcs]Quantity [pcs]Quantity [pcs]Quantity [pcs]Ø nominal (±5%) [mm]Nominal weight (±10%) [kg/km]
12T x 4F48412127.847
12T x 6F72612127.848
12T x 8F96812127.849
12T x 10F1201012127.850
12T x 12F1441212127.852

Main mechanical and environmental characteristics

Test Test StandardSpecified Value Requirement*
Max allowed tensionIEC 60794–1-21-E1 1500 NΔεf≤0.33%, ∆α reversible
Max operating tensionIEC 60794–1-21-E1 550 Nεf≤0.05%, ∆α ≤ 0.05 dB/km
Crush IEC 60794–1–21-E3 600 N / 100 mm, max. 15 min∆α reversible, no significant damage
ImpactIEC 60794–1–21-E45Nm, 3 impacts, R= 300 mm∆α≤0.05 dB after the test
TorsionIEC 60794–1–21-E7 100N, +/- 180°, 10 cycles∆α≤0.05 dB, no damage
Repeated Bending IEC 60794–1–21-E6R=20x D, 100N, 35 cyclesno damage
Cable Bend IEC 60794–1–21-E11 R=20x D, 4 turns, 3 cycles ∆α≤0.05 dB, no damage
Temperature CyclingIEC 60794–1–22-F1 -15°C to +60°C
-30°C to +70°C
∆α≤0.05 dB/km
∆α≤0.10 dB/km
Water Penetration IEC 60794–1–22-F5Bsample=3m, water column=1m, 24hno water leakage

(*) values for single-mode fibres, all optical measurements performed at @1550nm