Min. bending radius in operation [mm] | Min. bending radius during installation [mm] | Max. pulling tension [N ] | Nominal weight [kg/km] | Nom. outer diameter [mm] | Nom. wire diameter [AWG ] |
---|---|---|---|---|---|
30 | 60 | 110 | 60 | 7.6 | 23 |
Max. DC Resistance [Ω/km] | Nom. Mutual Capacity [pF/m] | NVP [%] | Mean input Impedance Ω | Delay Skew [ns/100m] | Segregation class | Coupling attenuation [dB] |
---|---|---|---|---|---|---|
95 | 45 | 80 | 100 ± 5 @ 100MHz | 5 | d | Min.80 |
Storage Temperature [ºC] | Operating Temperature [ºC] | During installation [ºC] |
---|---|---|
-20 to +70 | -20 to +70 | 0 to +50 |
Jacket material | Flammability | Calorific value [MJ/m ] |
---|---|---|
LSFRZH | Zgodnie z IEC 60332-3-24, IEC 60754-1/2; IEC 61034-1/2 EN50575; DCA-s2,d1,a1; DoP 0012 | 0,62 |
Frequency [MHz] | Attenuation [dB/100m (max.)] | NEXT [dB (min.)] | PS-NEXT [dB (min.)] | ACR-F [dB/100m (min.) ] | PS-ACR-F [dB/100m (min.) ] | RL [dB/100m (min.)] |
---|---|---|---|---|---|---|
4 | 3,6 | 100 | 100 | 91,2 | 88,2 | 28,0 |
16 | 7,2 | 100 | 100 | 89,4 | 86,4 | 30,0 |
20 | 8,0 | 100 | 100 | 89,0 | 86,0 | 30,0 |
31,25 | 10,0 | 100 | 100 | 88,0 | 85,0 | 28,6 |
62,5 | 14,2 | 100 | 97,5 | 85,9 | 82,9 | 26,5 |
100 | 18,1 | 97,4 | 94,4 | 84,0 | 81,0 | 25,1 |
155 | 22,7 | 94,5 | 91,5 | 81,7 | 78,7 | 23,8 |
200 | 25,8 | 92,9 | 89,9 | 80,1 | 77,1 | 23,0 |
240 | 29 | 91,7 | 88,7 | 78,5 | 75,8 | 22,4 |
250 | 31,9 | 91,4 | 88,4 | 75,7 | 75,5 | 22,3 |
350 | 34,6 | 89,2 | 86,2 | 75,7 | 72,7 | 22,3 |
500 | 41,8 | 86,9 | 83,9 | 72,1 | 69,1 | 22,3 |
650 | 43,2 | 82,2 | 81,0 | 70,9 | 66,8 | 22,3 |