Double jacket cable with multitube structure, glass yarn reinforcement,
and corrugated steel armouring – DSC-CI
Variant | Fibres [pcs] | Fibres per tube [pcs] | Total elements [pcs] | Active tubes [pcs] | Ø nominal (±5%) [mm] | Nominal weight (±10%) [kg/km] | Max short term tensile load ɛ≤0,5% [N] | Max short term tensile load ɛ≤0,33% [N] | Max long term tensile load [N] |
---|---|---|---|---|---|---|---|---|---|
1-6T x 6F | 6-36 | 6 | 6 | 1-6 | 11,4 | 168 | 4000 | 2700 | 1400 |
1-6T x 12F | 12-72 | 12 | 6 | 1-6 | 11,4 | 169 | 4000 | 2700 | 1400 |
8T x 12F | 96 | 12 | 8 | 8 | 13,2 | 203 | 4000 | 2700 | 1400 |
12T x 12F | 144 | 12 | 12 | 12 | 15,2 | 269 | 4000 | 2700 | 1400 |
Crush performance | Bending radius | Water penetration | Temperature range |
4000 [N/10 cm] | Static: 20 x D | 3[m] sample | Installation: -15... +55 [°C] |
IEC 60794-1-21-E3 | Dynamic: 30 x D | 1[m] head | Operation: -40… +70 [°C] |
Δα reversible | IEC 60794-1-21-E6 | 24[h] | Transport & Storage: -40… +70 [°C] |
Δα≤0,05 dB | IEC 60794-1-22-F5 | ||
no leakage | |||